Analysis and Control of Piezoelectric Miniature Pump

Subscription Access

Authors

  • Jirasak Saetan Department of Mechanical Engineering, Kasetsart University, 50 Phaholyothin Road, Jatujak, Bangkok 10900, Thailand Author
  • Nyesunthi Apiwattanalunggarn Department of Mechanical Engineering, Kasetsart University, 50 Phaholyothin Road, Jatujak, Bangkok 10900, Thailand Author

DOI:

https://doi.org/10.5890/JVTSD.2025.09.005

Abstract

This research aims to enhance the efficiency of a valveless piezoelectric miniature pump through the implementation of feedback control. Finite element analysis reveals that the motion of the structure impacts pumping efficiency. Using plant identification, a linear finite-element model of the miniature pump is reduced to a single-mode model with a single input. To increase the pumping efficiency, a closed-loop tracking control based on a nonlinear control technique, i.e. exact feedback linearization, is employed. The closed-loop miniature pump outperforms the open-loop miniature pump in terms of settling time and the pressure load existence at an outlet of the miniature pump, also improving efficiency by tracking a reference signal with two frequencies.

References

[1] Asadi Dereshgi, H., Dal, H., and Yildiz, M.Z. (2021), Piezoelectric micropumps: state of the art review, Microsystem Technologies, 27, 4127–4155.

[2] Ardito, R., Bertarelli, E., Corigliano, A., and Gafforelli, G. (2013), On the application of piezolaminated composites to diaphragm micropumps, Composite Structures, 99, 231–240.

[3] Wang, J., Zhao, X., Chen, X., and Yang, H. (2019), A Piezoelectric resonance pump based on a flexible support, Micromachines, 10(3), 169.

[4] Srinivasa Rao, K., Hamza, M., Ashok Kumar, P., and Girija Sravani, K. (2020), Design and optimization of MEMS based piezoelectric actuator for drug delivery systems, Microsystem Technologies, 26, 1671-1679.

[5] Farshchi Yazdi, S.A.F., Corigliano, A., and Ardito, R. (2019), 3-D Design and Simulation of a Piezoelectric Micropump, Micromachines, 10(4), 259.

[6] Liu, X., Li, X., Wang, M., Cao, S., Wang, X., and Liu, G. (2022), A High-performance Piezoelectric Micropump with multi-chamber in series, Applied Sciences, 12(9), 4483.

[7] Olsson, A., Stemme, G., and Stemme, E. (1995), A valve-less planar fluid pump with two pump chambers, Sensors and Actuators A: Physical, 47(1-3), 549-556.

[8] Guo, L., Yan, W., Xu, Y., and Chen, Y. (2012), Valveless piezoelectric micropump of parallel double chambers, International Journal of Precision Engineering and Manufacturing, 13, 771-776.

[9] Peng, T., Guo, Q., Yang, J., Xiao, J., Wang, H., Lou, H., and Liang, X. (2019), A high-flow, self-filling piezoelectric pump driven by hybrid connected multiple chambers with umbrella-shaped valves, Sensors and Actuators B: Chemical, 301.

[10] Pan, Q.S., He, L.G., Huang, F.S., Wang, X.Y., and Feng, Z.H. (2015), Piezoelectric micropump using dual-frequency drive. Sensors and Actuators A: Physical, 229, 86–93.

[11] Woo, J., Sohn, D.K., and Ko, H.S. (2020), Performance and flow analysis of small piezo pump, Sensors and Actuators A: Physical, 301.

[12] Huang, W., Lai, L., Chen, Z., Chen, X., Huang, Z., Dai, J., Zhang, F., and Zhang, J. (2021), Research on a Piezoelectric pump with flexible valves, Applied Sciences, 11(7), 2909.

[13] Woias, P. (2005), Micropumps—past, progress and future prospects, Sensors and Actuators B: Chemical, 105(1), 28-38.

[14] Stemme, E. and Stemme, G. (1993), A valveless diffuser/nozzle-based fluid pump, Sensors and Actuators A: Physical, 39(2), 159-167.

[15] Yan, Q., Yin, Y., Sun, W., and Fu, J. (2021), Advances in valveless piezoelectric pumps, Applied Sciences, 11(15), 7061.

[16] Singh, S., Kumar, N., George, D., and Sen, A.K. (2015), Analytical modeling, simulations and experimental studies of a PZT actuated planar valveless PDMS micropump, Sensors and Actuators A: Physical, 225, 81-94.

[17] Bußmann, A., Leistner, H., Zhou, D., Wackerle, M., Congar, Y., Richter, M., and Hubbuch, J. (2021), Piezoelectric Silicon Micropump for Drug Delivery Applications, Applied Sciences, 11(17), 8008.

[18] Ni, J., Xuan, W., Li, Y., Chen, J., Li, W., Cao, Z., Dong, S., Jin, H., Sun, L., and Luo, J. (2023), Analytical and experimental study of a valveless piezoelectric micropump with high flowrate and pressure load, Microsystems & Nanoengineering, 9, 72.

[19] Spencer, W.J., Corbett, W.T., Dominguez, L., and Shafer, B.D. (1978), An electronically controlled piezoelectric insulin pump and valves, IEEE Transactions on Sonics and Ultrasonics, 25, 153-156.

[20] Gass, V., van der Schoot, B.H.,Jeanneret, S., and de Rooij, N.F. (1994), Integrated flow-regulated silicon micropump, Sensors and Actuators A: Physical, 43, 335-338.

[21] Kaçar, A., Özer, M.B., and Taşcıoğlu, Y. (2020), A novel artificial pancreas: energy efficient valveless Piezoelectric actuated closed-loop insulin pump for T1DM, Applied Sciences, 10(15), 5294.

[22] Chen, L., Liu, Y., Sun, L., Qu, D., and Min, J. (2010), Intelligent control of Piezoelectric Micropump based on MEMS flow sensor, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems, Taipei, Taiwan, 3055-3060.

[23] Yeming, S. and Junyao, W. (2019), Digitally-controlled driving power supply for dual-active-valve piezoelectric pump, Microsystem Technologies, 25, 1257–1265.

[24] Erturk, A. and Inman, D.J. (2011), Piezoelectric Energy Harvesting, John Wiley & Sons.

[25] Meirovitch, L. (1997), Principles and Techniques of Vibrations, Prentice Hall.

[26] Gerhart, P.M., Gerhart, A.L., and Hochstein, J.I. (2017), Munson's Fluid Mechanics, Wiley.

[27] Apiwattanalunggarn, P., Shaw, S.W., Pierre, C., and Jiang, D. (2003), Finite-element-based nonlinear modal reduction of a rotating beam with Large-Amplitude motion, Journal of Vibration and Control, 9(3-4), 235-263.

[28] Khalil, H.K. (2002), Nonlinear Systems, Prentice Hall.

Article Metrics

Citations 0 Crossref
PublishedSeptember 2025

Usage tracking begins September 1, 2026.

History Published

Issue

Section

Research Articles

How to Cite

Saetan, J., & Apiwattanalunggarn, N. (2026). Analysis and Control of Piezoelectric Miniature Pump. Journal of Vibration Testing and System Dynamics, 9(3), 261-279. https://doi.org/10.5890/JVTSD.2025.09.005