Analysis and Control of Piezoelectric Miniature Pump
DOI:
https://doi.org/10.5890/JVTSD.2025.09.005Abstract
This research aims to enhance the efficiency of a valveless piezoelectric miniature pump through the implementation of feedback control. Finite element analysis reveals that the motion of the structure impacts pumping efficiency. Using plant identification, a linear finite-element model of the miniature pump is reduced to a single-mode model with a single input. To increase the pumping efficiency, a closed-loop tracking control based on a nonlinear control technique, i.e. exact feedback linearization, is employed. The closed-loop miniature pump outperforms the open-loop miniature pump in terms of settling time and the pressure load existence at an outlet of the miniature pump, also improving efficiency by tracking a reference signal with two frequencies.References
[1] Asadi Dereshgi, H., Dal, H., and Yildiz, M.Z. (2021), Piezoelectric micropumps: state of the art review, Microsystem Technologies, 27, 4127–4155.
[2] Ardito, R., Bertarelli, E., Corigliano, A., and Gafforelli, G. (2013), On the application of piezolaminated composites to diaphragm micropumps, Composite Structures, 99, 231–240.
[3] Wang, J., Zhao, X., Chen, X., and Yang, H. (2019), A Piezoelectric resonance pump based on a flexible support, Micromachines, 10(3), 169.
[4] Srinivasa Rao, K., Hamza, M., Ashok Kumar, P., and Girija Sravani, K. (2020), Design and optimization of MEMS based piezoelectric actuator for drug delivery systems, Microsystem Technologies, 26, 1671-1679.
[5] Farshchi Yazdi, S.A.F., Corigliano, A., and Ardito, R. (2019), 3-D Design and Simulation of a Piezoelectric Micropump, Micromachines, 10(4), 259.
[6] Liu, X., Li, X., Wang, M., Cao, S., Wang, X., and Liu, G. (2022), A High-performance Piezoelectric Micropump with multi-chamber in series, Applied Sciences, 12(9), 4483.
[7] Olsson, A., Stemme, G., and Stemme, E. (1995), A valve-less planar fluid pump with two pump chambers, Sensors and Actuators A: Physical, 47(1-3), 549-556.
[8] Guo, L., Yan, W., Xu, Y., and Chen, Y. (2012), Valveless piezoelectric micropump of parallel double chambers, International Journal of Precision Engineering and Manufacturing, 13, 771-776.
[9] Peng, T., Guo, Q., Yang, J., Xiao, J., Wang, H., Lou, H., and Liang, X. (2019), A high-flow, self-filling piezoelectric pump driven by hybrid connected multiple chambers with umbrella-shaped valves, Sensors and Actuators B: Chemical, 301.
[10] Pan, Q.S., He, L.G., Huang, F.S., Wang, X.Y., and Feng, Z.H. (2015), Piezoelectric micropump using dual-frequency drive. Sensors and Actuators A: Physical, 229, 86–93.
[11] Woo, J., Sohn, D.K., and Ko, H.S. (2020), Performance and flow analysis of small piezo pump, Sensors and Actuators A: Physical, 301.
[12] Huang, W., Lai, L., Chen, Z., Chen, X., Huang, Z., Dai, J., Zhang, F., and Zhang, J. (2021), Research on a Piezoelectric pump with flexible valves, Applied Sciences, 11(7), 2909.
[13] Woias, P. (2005), Micropumps—past, progress and future prospects, Sensors and Actuators B: Chemical, 105(1), 28-38.
[14] Stemme, E. and Stemme, G. (1993), A valveless diffuser/nozzle-based fluid pump, Sensors and Actuators A: Physical, 39(2), 159-167.
[15] Yan, Q., Yin, Y., Sun, W., and Fu, J. (2021), Advances in valveless piezoelectric pumps, Applied Sciences, 11(15), 7061.
[16] Singh, S., Kumar, N., George, D., and Sen, A.K. (2015), Analytical modeling, simulations and experimental studies of a PZT actuated planar valveless PDMS micropump, Sensors and Actuators A: Physical, 225, 81-94.
[17] Bußmann, A., Leistner, H., Zhou, D., Wackerle, M., Congar, Y., Richter, M., and Hubbuch, J. (2021), Piezoelectric Silicon Micropump for Drug Delivery Applications, Applied Sciences, 11(17), 8008.
[18] Ni, J., Xuan, W., Li, Y., Chen, J., Li, W., Cao, Z., Dong, S., Jin, H., Sun, L., and Luo, J. (2023), Analytical and experimental study of a valveless piezoelectric micropump with high flowrate and pressure load, Microsystems & Nanoengineering, 9, 72.
[19] Spencer, W.J., Corbett, W.T., Dominguez, L., and Shafer, B.D. (1978), An electronically controlled piezoelectric insulin pump and valves, IEEE Transactions on Sonics and Ultrasonics, 25, 153-156.
[20] Gass, V., van der Schoot, B.H.,Jeanneret, S., and de Rooij, N.F. (1994), Integrated flow-regulated silicon micropump, Sensors and Actuators A: Physical, 43, 335-338.
[21] Kaçar, A., Özer, M.B., and Taşcıoğlu, Y. (2020), A novel artificial pancreas: energy efficient valveless Piezoelectric actuated closed-loop insulin pump for T1DM, Applied Sciences, 10(15), 5294.
[22] Chen, L., Liu, Y., Sun, L., Qu, D., and Min, J. (2010), Intelligent control of Piezoelectric Micropump based on MEMS flow sensor, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems, Taipei, Taiwan, 3055-3060.
[23] Yeming, S. and Junyao, W. (2019), Digitally-controlled driving power supply for dual-active-valve piezoelectric pump, Microsystem Technologies, 25, 1257–1265.
[24] Erturk, A. and Inman, D.J. (2011), Piezoelectric Energy Harvesting, John Wiley & Sons.
[25] Meirovitch, L. (1997), Principles and Techniques of Vibrations, Prentice Hall.
[26] Gerhart, P.M., Gerhart, A.L., and Hochstein, J.I. (2017), Munson's Fluid Mechanics, Wiley.
[27] Apiwattanalunggarn, P., Shaw, S.W., Pierre, C., and Jiang, D. (2003), Finite-element-based nonlinear modal reduction of a rotating beam with Large-Amplitude motion, Journal of Vibration and Control, 9(3-4), 235-263.
[28] Khalil, H.K. (2002), Nonlinear Systems, Prentice Hall.
Article Metrics